Ultradent™ LC Block-Out Resin

Ultradent LC Block-Out Resin

Ultradent LC Block-Out Resin provides reservoir space for bleaching trays. It’s also useful for other laboratory procedures such as model and die repairs. Ultradent LC Block-Out Resin can be rapidly and efficiently delivered with the Black Mini tip. It must be light cured and is not intended for intraoral use.

  • Low viscosity for easy flow
  • Blue pigment for easy visibility
  • Great utility resin with numerous uses

 

 

Contents


  • Kit
    – 4 x 1.2 ml Ultradent LC Block-Out Resin syringes
    – 20 x Black Mini tips
  • Econo Kit
    – 20 x 1.2 ml Ultradent LC Block-Out Resin syringes
    – 20 x Black Mini tips

Product Details


Ultradent LC Block-Out Resin provides reservoir space for bleaching trays. It’s also useful for other laboratory procedures such as model and die repairs. Ultradent LC Block-Out Resin can be rapidly and efficiently delivered with the Black Mini tip. It must be light cured and is not intended for intraoral use.

  • Low viscosity for easy flow
  • Blue pigment for easy visibility
  • Great utility resin with numerous uses

 

Indications for Use


Ultradent LC Block-Out Resin is a viscous methacrylate-based utility resin used for creating reservoir space in bleaching trays. This light-cured material is delivered via syringe, and its blue color makes it easy to see for precise delivery.

 

Clinicals


 

Technical Details


Multipurpose Resin
Ultradent LC Block-Out Resin is ideal for creating reservoir space in whitening trays, but it can do so much more! Use it for lab procedures requiring spacing or undercut block out, and to repair small fractures or voids in laboratory models.

Ideal Viscosity
​Placing a resin on a stone model requires that the resin not slump or migrate as the stone model is rotated. Ultradent LC Block-Out Resin features an ideal viscosity that prevents the resin from moving to areas where it’s not intended to go.

Easy to Use
Ultradent LC Block-Out Resin features a no-mix formula that is easily delivered via syringe, allowing for precise placement.

 

Procedures


Whitening TrayLab Sales Sheet

 

How to Use

Tray Fabrication Step by Step

– See Instructions for Use for complete instructions, warnings, and precautions.

  1. Pour impression with fast-set plaster or dental stone. Pour alginate shortly after making impression to ensure accuracy. Trimming is less work if quantity of stone is kept to a minimum. Palate and tongue areas are not poured or should be removed after plaster has set. Allow model to dry two hours.
    1_Tray-Fabrication-Step-by-Step-Ultradent


    2. For reservoir spaces, apply Ultradent LC Block-Out resin approximately 0.5 mm thick onto labial surfaces and approximately 1.5 mm shy of the gingival margin. DO NOT extend onto incisal edges or occlusal surfaces. Using a VALO curing light, cure each tooth 5 seconds. Wipe off oxygen inhibition layer.
    2_Tray-Fabrication-Step-by-Step-Ultradent


    3. With a vacuum former, heat tray material (Sof-Tray Classic Sheets) until it sags approximately ¼” to ½” for the 0.035″ material and 1″ for the thicker material (0.060″ and 0.080″). Adapt plastic over model. Cool and remove model from the vacuum former. Cut excess bulk of material away with serrated plastic trimmers (e.g. Ultradent Utility Cutters).

    3_Tray-Fabrication-Step-by-Step-Ultradent-updated


    4. With small tactile scissors (e.g. Ultradent Ultra-Trim Scalloping Scissors), carefully and precisely trim the tray to the clear line which is at the gingival height. Scallop edges to avoid contact with gingival tissue.

    4_Tray-Fabrication-Step-by-Step-Ultradent


    5. Return tray to model; check tray extensions. Gently flame polish the edges one quadrant at a time, if necessary, with a butane torch. While still warm, immediately hold periphery of each segment firmly against model for three seconds with water-moistened gloved finger. If this over-thins the tray material, fabricate a new tray.

    5_Tray-Fabrication-Step-by-Step-Ultradent


    6. Review enclosed instructions with patient to brush teeth and explain the process of loading the tray by expressing one continuous bead of gel approximately halfway up from the incisal edge on the facial side of the tray from molar to molar. Explain that this should use about 1/2 to 1/3 of a syringe.

    6_Tray-Fabrication-Step-by-Step-Ultradent


    7. Place tray over teeth. Gently press tray to move gel into place. Pressing too firmly will force gel out of tray.

    7_Tray-Fabrication-Step-by-Step-Ultradent-1


    8. Remove excess gel with a soft toothbrush.